7
Commissioning
The most important codes for commissioning
EDK82EV113 DE/EN/FR 8.1
L
146
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0007
uSEr
(cont.)
E4 E3 E2 E1
41
JOG1/3 DCB TRIP set DFIN1−ON
42
QSP DCB TRIP set DFIN1−ON
43
CW/CCW QSP TRIP set DFIN1−ON
44
UP DOWN PAR DFIN1−ON
45
CW/CCW QSP PAR DFIN1−ON
46
H/Re PAR QSP JOG1/3
47
CW/QSP CCW/QSP H/Re JOG1/3
48
PCTRL1−
OFF
DCB
PCTRL1−I−
OFF
DFIN1−ON
49
PCTRL1−
OFF
JOG1/3 QSP DFIN1−ON
50
PCTRL1−
OFF
JOG1/3
PCTRL1−I−
OFF
DFIN1−ON
51
DCB PAR
PCTRL1−I−
OFF
DFIN1−ON
255 Free configuration under C0410 Only display
Do not change C0007 since settings
under C0410 can be lost
C0010
uSEr
Minimum output
frequency
0.00 0.00
à14.5 Hz
{0.02 Hz} 650.00
l C0010 is not effective with bipolar
setpoint selection (−10 V ... + 10 V)
l C0010 only limits the analog input
1
àSpeed setting range 1 : 6 for
Lenze geared motors: Setting
absolutely required for operation
with Lenze geared motors.
C0011
uSEr
Maximum output
frequency
50.00 7.50
à87 Hz
{0.02 Hz} 650.00
C0012
uSEr
Acceleration time
main setpoint
5.00 0.00 {0.02 s} 1300.00 Reference: frequency change 0 Hz ...
C0011
l Additional setpoint ð C0220
l Acceleration times can be
activated via digital signals
ð
C0101
C0013
uSEr
Deceleration
time main
setpoint
5.00 0.00 {0.02 s} 1300.00 Reference: frequency change
C0011 ... 0 Hz
l Additional setpoint ð C0221
l Deceleration times can be
activated via digital signals
ð
C0103