Operation and Software
98 BA8230
05 DIGITALE E/As
D-input 1:14 Motpot up
Select fixed speed 1
D-input 2:15 Motpot down
Select fixed speed 2
Ext. Ramp choise
D-input 3:16 Jogging
Parametersatzumschaltung
Select ramp 2
Select fixed speed 3
D-output 1:23/:24 Speed = ref.
Speed = Zero
Speed > N-ref
Laststrom > IL-ref
Warning
Var. for:23/:24
Invert. :23/:24 No
Yes
Band speed = ref. 30.00
Band speed = zero 3.00
Reference speed 750.00
Ref. load current 100.00
06 RATINGS
Nom. inverter voltage 400 V
460 V
Only display Inverter kVA 178...335 kVA
Mains voltage 380 ...480 V
Brake type AC: without
AC: with
DC: with/ without
Nom.motor power 110 kW
Nom.motor voltage 380 V
Nom.motor speed 1460 1/min
Nom.motor frequ. 50 Hz
Switching mode Delta
Star
Nom.motor curr. 250 A
cos phi 0.85
Stall torque/Rated torque 3.0
M
rated
/M
stall
50 %
Number of strokes 1000
Protection level 2 Adjust mode No
Yes
Adjust to 0 0.00
Protection level 1 R-stator + R-cable. 0.5773
Protection level 2 Fan trigger 0 ... 65 ºC