92 BA8230
4.1.2 Control philosophy Operation of the unit with the 8230 frequency inverter control unit is divided into 3
control levels:
1) "Select main menu"
2) "Select Parameter"
3) "Select from list” or “Adjust a parameter value"
You move to the next lower control level using the “Enter” (4) key. You move back to
the next higher level with the “Menu” key (3).
Select Enter Select Enter Select list
Hauptmenu Menü Parameter Menü Adjust value
In the “Select main menu” or “Select parameter” mode you can select a main menu
option for the parameter using the “Up” (5) and "Down" (6) keys.
In the “Select list / Adjust value” mode you can either select from a list
(Example: Language: German / English / French) or adjust parameter values
(eg. maximum speed: 1270 rpm 1480 rpm).
Parameters from the Select list are selected using the “Up” (5) and "Down" (6)
keys.
If you select “Adjust a parameter value” using “Enter” (4), the number before
the decimal point is selected first. This can then be adjusted with the Up(5) or
Down (6) keys. When you have selected the right-hand number you can save
your entry by pressing the “Enter” (4) key.
If you made an adjustment in the “Select list/Adjust value” mode and saved it,
this is indicated by the message “Info: Parameter adjusted” (the word “Info” will
flash). This message will disappear after 2 seconds. It tells the operator that a
change was made on this level.