Operation and Software
BA8230 123
4.4.6 Ratings Inverter-nominal voltage
This parameter determines the value of the corresponding rated mains voltage of the
inverter.
As supplied: Unit-based
Inverter kVA
This parameter specifies controller-specific references for the controller power.
This parameter can only be changed or entered again if the control board is replaced
or the software is updated.
As supplied: Unit-based
Mains voltage
This parameter tells the control the rated mains supply voltage. The value entered is
used to determine the operating range, monitoring of link charging and the starting
voltage for special facilities such as “Support”.
Adjustment range: 380 V ... 480 V
As supplied: 400 V