Object-Nr. Parameter Default setting Unit Value
01=DISPLAY
2009 Drive Name ...................
206A Date/Time ...................
02=Application Par.
3225 Speed limit 1499.91 1/min ................
3220 Ref. overspeed
1)
1800 1/min ................
4282 Crnt.lmt.max.mot. 144.4 % ................
4283 Crnt.lmt.max.gen. 100.0 % ................
4281 Crnt.lmt.nom.gen.
1)
100.0 % ................
4280 Crnt.lmt.nom.mot.
1)
100.0 % ................
3810 Ramp up 2000.0 ms ................
3812 Ramp down 5000.0 ms ................
3814 Ramp fast stop 500.0 ms ................
3710 Motpot ramp up 10.000 s ................
3711 Motpot ramp down 10.000 s ................
3712 Motpot n-max 1499.9 1/min ................
3713 Motpot n-min 0.0 1/min ................
3204 Jogging speed 29.85 1/min ................
3200 Fixed speed 1 149.97 1/min ................
3201 Fixed speed 2 299.95 1/min ................
3202 Fixed speed 3 449.92 1/min ................
3203 Fixed speed 4 599.89 1/min ................
3830 Skip speed 1 750.0 1/min ................
3831 Skip band 1 0.0 1/min ................
3832 Skip speed 2 1500.1 1/min ................
3833 Skip band 2 0.0 1/min ................
3834 Skip speed 3 2250.1 1/min ................
3835 Skip band 3 0.0 1/min ................
03=CONFIGURATION
3103 Reaction OFF Discharge dc link ................
3107 Motpot reset Reset at OFF ................
3108 Lock monitor Yes ................
2069 Auto Restart Time 0.000 s ................
3260 Manual - control Control or Terminal ................
3A80 Manual - demand Motpot ................
3261 AUTO - control Terminal ................
3A82 AUTO - demand Motpot ................
3105 MAN/AUTO c/over At standstill ................
3109 Invert:21/22 No ................
4012 capture mode
2)
No
Direction drive 1 ................
3120 Kinetik support
1)
No ................
205D Parameter Set Nr. 1 ................
205F Copy Target: Set Nr.
2)
0 ................
3121 Term.ParSet chan. Disabled ................
439A Puls frequency