Operation and Software
120 BA8230
Select fixed speed 1 Select fixed speed 2 Activated fixed speed
0 0 "Fixed speed 1"
1 0 "Fixed speed 2"
0 1 "Fixed speed 3"
1 1 "Fixed speed 4"
"Fixed speed 1" to "Fixed speed 4" are specified in 02 = APPLICATION
PARAMETERS.
IMPORTANT!
If the function of the D-Input terminal :15 is not set to "Select fixed speed 2", the
selection matrix for Select fixed speed 2 is 0.
The active fixed speeds are only effective if the parameter for MANUAL demand or
AUTO demand in Menu 03 Configuration is set to fixed speed.
D-Input 3 terminal 16
This parameter determines the function of the digital control input at terminal :16. The
function is active at logic “High”.
Select list: - Jogging
- Parameter set changeover
As supplied: Jogging
The “Jogging” function switches the system to the “Jogging demand” on the demand
channel (see Application parameters).