Commissioning
Test commissioning
Test commissioning with terminal control
7
91
EDS84ABD302 EN 4.0
4. Enable controller:
Set terminal X4/RFR to HIGH-Potential (reference: X4/GND).
5. Vary the motor speed or the motor velocity with the potentiometer or by defining
different fixed setpoints:
DI2 DI1 Motor speed
00Setpoint by potentiometer
0 1 40 % of C00011 (reference speed)
1 0 60 % of C00011 (reference speed)
1 1 80 % of C00011 (reference speed)
Internal Keypad Code Subcode Motor speed
-2-
_
`
C...
C051
xxxx
C00051 - Observe
z the actual speed value:
C00051
z appearing messages 92
6. Save the settings with mains failure protection by entering the value ”1” in code
C002, subcode 7.