7.3 Menu structure
Note!
ƒ After switching on the controller, the integrated keypad performs a quick
self-test. All segments of the display flash for approx. 2 seconds.
After that:
ƒ if there is no fault the keypad displays rdy for 1 second.
– If power-up start is disabled the keypad displays 00.
– if power-up start is enabled the keypad displays the limited setpoint speed
of the motor. The integrated keypad is now operational.
ƒ If there is a fault then the keypad displays the corresponding message.
ƒ When the password protection is activated and no password i s input, only
the user menu is freely accessible. All other functions require the correct
password.
-5-
c___
_
`
....
PASS
2 sec.
0000
C___
`
....
_
_
`
`
....
0001
....
`
_
......
-2-
_
_
`
-1-
_
`
-0-
CAL
CAL/StoP
CAL/Err
bF
CL
FCL
FSt
dEC
br
_
`
....
84BLMEN001
Level
n Status display
o Password request and password input
p Menu level
q Code level
r Subcode level
s Edit
Menu
-0- Access all the parameters which the user has selected under C517 by theirselves.
-1- Access all drive parameters.
-2- Access parameters for fast commissioning with terminal control.
-3- Access parameters for fast commissioning with keypad control.
-4- Access motor control parameters.
-5- Access diagnostic parameters.