EasyManua.ls Logo

Lenze 8400 BaseLine C - Menu Structure

Lenze 8400 BaseLine C
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
Menu structure
7
85
EDS84ABD302 EN 4.0
7.3 Menu structure
Note!
ƒ After switching on the controller, the integrated keypad performs a quick
self-test. All segments of the display flash for approx. 2 seconds.
After that:
ƒ if there is no fault the keypad displays rdy for 1 second.
If power-up start is disabled the keypad displays 00.
if power-up start is enabled the keypad displays the limited setpoint speed
of the motor. The integrated keypad is now operational.
ƒ If there is a fault then the keypad displays the corresponding message.
ƒ When the password protection is activated and no password i s input, only
the user menu is freely accessible. All other functions require the correct
password.
-5-
c___
_
`
....
PASS
2 sec.
0000
C___
`
....
_
_
`
`
....
0001
....

`
_
......
-2-
_
_
`
-1-
_
`
-0-
CAL
CAL/StoP
CAL/Err
bF
CL
FCL
FSt
dEC
br
_
`
....
84BLMEN001
Level
n Status display
o Password request and password input
p Menu level
q Code level
r Subcode level
s Edit
Menu
-0- Access all the parameters which the user has selected under C517 by theirselves.
-1- Access all drive parameters.
-2- Access parameters for fast commissioning with terminal control.
-3- Access parameters for fast commissioning with keypad control.
-4- Access motor control parameters.
-5- Access diagnostic parameters.