Electrical installation
Control terminals
Analog input
6
75
EDS84ABD302 EN 4.0
6.5.3 Analog input
X4
8400BLGG004
Fig. 6-17 Wiring and shielding of the analog input
Terminal X4 Labelling Description
GND
A1U
AR
12I
RFR
DI1
DI2
DI3
DI4
24E
DO1
GND GND connection for analog and digital signals
A1U Analog input 1
z For master voltage/master
current configuration see
C00034
±10 V ( 75)
AR Analog Reference reference voltage 10 V
84BDLGGX005
Terminal data
Max. conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
flexible
0.2 ... 1.5
24 ... 16 0.5 4.5 3.5 x 0.6
with wire end ferrule