Commissioning
Display elements and control panel
7
83
EDS84ABD302 EN 4.0
7.2 Display elements and control panel
84BLKP0001
Pos. Description
c 4-Character- Display with LEDs (A ... F)
A orange Set current/torque limit is reached.
B yellow Minus sign for identifying the negative numbers bigger than 3 characters
C yellow User-LED- configured with C00621/42.
D red
see table below
E green
F
yellow Rotational direction CWW
off Rotational direction CW
blinking Commanded direction is not equal to actual direction- for example during reversing.
ESC ESC key Abort of the current operation
↵ Enter key Confirm and accept changes
Navigation key,
upwards
Short pressing: navigation in the menu level and parameter level and parameter editing
Long pressing (> 2 seconds): fast scrolling function
Navigation key,
downwards
The LEDs ”D” and ”E” have an additional signalling.
LED E
(green)
LED D
(red)
Status
OFF OFF → ”Init” state
OFF → ”ReadyToSwitchOn” state
OFF → ”SwitchedOn” state
OFF → ”OperationEnabled” state
→ ”Warning” status display
The controller is ready to switch on, switched on or operation is enabled and
there is a warning pending.
OFF → ”Trouble” state
OFF → ”Fault” state
OFF → ”SystemFail” state