Technical data
Overcurrent operation
Device overload for 15-s cycle
4
37
EDS84ABD302 EN 4.0
4.3.1 Device overload for 15-s cycle
Operation at rated mains voltage 230 V
Type
I
amax
/I
aN8
[%] in 15-s cycle c
f=2kHz f=4kHz f=8kHz f = 16 kHz
E84AVBxx2512
200
75 200 75 200 75 133 50
E84AVBxx3712
E84AVBxx5512
E84AVBxx7512
E84AVBxx1122
E84AVBxx1522
E84AVBxx2222
Operation at rated mains voltage 400 V
Type
I
amax
/I
aN8
[%] in 15-s cycle c
f=2kHz f=4kHz f=8kHz f = 16 kHz
E84AVBxx3714
175
80 175 80 175 80 133 50
E84AVBxx5514
E84AVBxx7514
E84AVBxx1124
E84AVBxx1524
E84AVBxx2224
E84AVBxx3024 170 80 170 80 170 80 133 50
Operation at rated mains voltage 500 V
Type
I
amax
/I
aN8
[%] in 15-s cycle c
f=2kHz f=4kHz f=8kHz f = 16 kHz
E84AVBxx3714
200
75 200 75 200 75 133 50
E84AVBxx5514
E84AVBxx7514
E84AVBxx1124
E84AVBxx1524
E84AVBxx2224
E84AVBxx3024