Electrical installation
Control terminals
Digital inputs and outputs
6
78
EDS84ABD302 EN 4.0
6.5.5 Digital inputs and outputs
X4
8400BLGG004
Fig. 6-20 Wiring and shielding of the digital inputs
DO1 The digital output is not available for devices with nameplate data
E84AVBDxxxxSX0
Terminal X4 Labelling Description
GND
A1U
AR
12I
RFR
DI1
DI2
DI3
DI4
24E
DO1
RFR Controller enable/controller inhibit, always required
DI1 Digital input 1
42
DI2 Digital input 2
DI3 Digital input 3
DI4 Digital input 4
DO1 Digital output
84BLGGX005
GND GND for analog and
digital signals
Terminal data
Max. conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
flexible
0.2 ... 1.5
24 ... 16 0.5 4.5 3.5 x 0.6
with wire end ferrule
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com