Electrical installation
Control terminals
Analog input
6
76
EDS84ABD302 EN 4.0
Example circuit
X4
E84AVBx...
AR
A1U
GND
+
10 V
-
" I/O Shields
X13
X4
-
+
E84AVBx...
AR
A1U
GND
+
10 V
-
" I/O Shields
X13
=
250 W
8400BLD009 8400BLD013
Fig. 6-18 Wiring examples of the analog input
Potentiometer with internal controller supply
External master current selection for a sensor signal 0 - 20 mA
X4 Terminal for the analog input and the digital inputs and output
X13 Terminal for I/O shields
GND GND connection for analog and digital signals