3 Short setup of the technology application
3.8 Step 7 (optional): Set optimisation parameters
28
Lenze · 8400 "Position Sequencer" technology application · Software manual · DMS 1.0 EN · 07/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Limit position monitoring
C01230 - Bit 3
(LS_MotionControl
Kernel)
Consideration of the software limit positions in MCK
"Manual jog" operating mode
0 Software limit positions not
active
1 Software limit positions active
(if the home position is known)
C00595/1...4
(LS_MotionControl
Kernel)
Response at the activation of limit position
monitoring
Subcode 1: response at the approach of the
positive limit switch.
Subcode 2: response at the approach of the
negative limit switch.
Subcode 3: response at overtravelling the positive
software limit position (C01229/1).
Subcode 4: response at overtravelling the
negative software limit position (C01229/2).
0No Reaction
1Fault
3TroubleQuickStop
4 WarningLocked
5 Warning
6Information
Error/status messages of the positioning sequence control
C00581/1...2
(LS_SetError_1)
Response to errors of the positioning sequence
control
Subcode 1: response if the time monitoring
function for the "Positioning" action has been
activated.
Subcode 2: response if the positioning sequence
control reports an error.
0No Reaction
1Fault
2Trouble
3TroubleQuickStop
4 WarningLocked
5 Warning
6Information
C00581/3
(LS_SetError_1)
Response if the positioning program has been
started and is pausing.
0No Reaction
1Fault
2Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6Information
Parameter
(Block)
Possible settings Info