Configuration
Function blocks
Internal motor control with vector control (MCTRL2)
8
8.2
8.2.7
8.2−47
EDSVF9383V EN 7.1−04/2012
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0904
CFG: DC−BREAK 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block MCTRL
l HIGH = Motor is braked
8.2−25
8.2−40
C0905 DIS: DC−BREAK 0 1 Function block MCTRL
l Display of the signal linked in
C0904
C0906 −199.99 {0.01 %} 199.99
Function block MCTRL
l Display of the signals linked in
C0890, C0891, C0892, C0893,
C0901 and C0903
8.2−25
8.2−40
1 DIS: N−SET
2 DIS: M−ADD
3 DIS: LO−M−LIM
4 DIS: HI−M−LIM
5 DIS: I−SET
6 DIS: BOOST
C0907 0 1
Function block MCTRL
l Display of the signals linked in
C0899, C0900 and C0902
1 reserved
2 DIS: N/M−SWT
3 DIS: QSP
4 DIS: I−LOAD
C0909 speed limit 1
1 +/− 175 %
Speed limitation, function block
MCTRL
l Limitation of direction of
rotation for the speed setpoint
8.2−25
8.2−40
2 0 ... 175 %
3 −175 ... 0 %
C0910
CFG: VP−ADAPT 1006 FIXED100% Selection list 1 Configuration of analog input
signal, function block MCTRL
l Gain adaptation of the speed
controller
l If the gain is varying, join to
CURVE−OUT of FB CURVE
8.2−25
8.2−40
C0911 DIS: VP−ADAPT −199.99 {0.01 %} 199.99 Function block MCTRL
l Display of the signal linked in
C0910
ƒ The signal at the input MCTRL−N−SET is the setpoint speed in [%] and
always refers to the maximum speed (C0011).
ƒ In most basic configurations, MCTRL−N−SET is connected to the function
block NSET (speed setpoint conditioning).
You can also connect MCTRL−N−SET to any other analog output signal
of a function block.
ƒ The speed setpoint at MCTRL−N−SET is always limited to ±100 % of the
maximum speed n
max
(C0011).
ƒ The motor control converts the speed setpoint into a frequency
setpoint, which is limited to a maximum output frequency, depending
on the switching frequency f
chop
Switching frequency f
chop
Maximum output frequency
2 kHz 150 Hz
4 kHz 300 Hz
Speed setpoint selection
Speed setpoint limitation

Table of Contents