Installing of the standard device
Basic devices in the power range 110 ... 200 kW
Drilling the holes into the mounting plate
4
4.2
4.2.2
4.2−2
EDSVF9383V EN 7.1−04/2012
4.2.2 Drilling the holes into the mounting plate
Assembly space Minimum clearance
Left/right of other controllers 30 mm
Left/right of a non−heat−conducting wall 100 mm
Top/bottom 200 mm
Comply with the clearances given to ensure a sufficient cooling of the
controller. When using an air lock, different clearances apply (see Mounting
Instructions for the air lock).
a1
a1
a3
a2
a2
d
b
93vec048
Fig. 4.2−2 Bore holes in the mounting plate for fixing the controller
a1 a2 a3 b d
450 mm 340 mm 225 mm 1005 mm 9 mm (12x)
1. Mark the bore holes on the mounting plate according to the figure.
2. Drill the holes into the mounting plate.