Configuration
Code table
8
8.5
8.5−8
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0067 Act trip Selection list 10 Momentary fault message
l Display only
C0070 Vp speed CTRL 10.0 0.0 {0.1 } 255.9 Gain of speed controller
8.2−25
8.2−40
C0071 Tn speed CTRL 50 1 {1 ms} 6000 Integral−action time of speed
controller
C0071 = 6000 ms: No
integral−action time
C0074 limit N 10.00 0.00 {0.01 %} 100.00 Limitation of the speed controller
l Influence of the speed
controller for V/f characteristic
control with feedback
l max. setpoint difference in
percent
8.2−25
8.2−40
C0075 Vp curr CTRL 0.04 0.00 {0.01 } 0.99 Gain of current controller
l Vector control: Gain of current
controller
l V/f characteristic control:
Maximum current controller
8.2−25
8.2−40
C0076 Tn curr CTRL 10.0 0.1 {0.1 ms} 2000.0 Integral−action time of current
controller
l Vector control: integral−action
time of current controller
l V/f characteristic control:
maximum current controller
l C0076 = 2000 ms: current
controller is switched off
8.2−25
8.2−40
C0077 Ti field CTRL 4.0 0.3 {0.1 ms} 6000.0 Integral−action time of field
controller
l Only active in case of vector
control with feedback
C0078 Tn slip CTRL 100 1 {1 ms} 6000 Integral−action time of slip
controller
l Filter time for slip
compensation (C0021)
l Only active with V/f
characteristic control
8.2−25
C0079 Adapt I−CTRL 100.0
0
10.00 {0.01 %} 100.00 Adaption of the current controller
l Evaluation for the reset time
T
ni
of the current controller
l Effective for setpoint = 0
l Is increased automatically to
100 % up to rated speed
l C0079 = 100 %: no adaption of
the reset time
l C0079 < 100 %:
evaluation of the reset time:
8.2−25
8.2−40
C0080 Vp field CTRL 0.50 0.00 {0.01 } 0.99 Influence on the motor
magnetising current selected
under C0095
l Not effective with C0006 = 1
and C0025 > 1 at the same
time
l Influence is effective from 0 Hz
to the frequency selected
under C1583
6.6−1
C0081
Mot power à 0.01 {0.01 kW} 500.00 Rated motor power
à Change of C0086 resets value
to factory setting
l Change of C0081 sets C0086 =
0