Configuration
Code table
8
8.5
8.5−19
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0195 BRK1 T act 99.9 0.0 {0.1 s} 99.9 Brake closing time, function block
BRK1
l C0195 = 99.9 s: infinite
l After the time has elapsed in
C0195, the status "brake
applied" is reached
See System
Manual
(extension)
C0196 BRK1 T release 0.0 0.0 {0.1 s} 60.0 Brake opening time, function
block BRK1
l Opening time can be obtained
from the technical data of the
brake
l After the time has elapsed in
C0196, the status "brake
released" is reached
C0200 S/W Id
x
y
Main version
Subversion
Software ID
l Display only
S9300MVxy000 9300 vector 0.37 ... 90 kW
S9300MVxy020 9300 vector 110 ... 400 kW
C0201 S/W date xxx yy zzzz xxx = month
yy = day
zzzz = year
Software creation
l Display only
C0202 Internal identification
l Display only
C0203 Commission number
l Display only
C0204 Serial number
l Display only
C0206 Product date xx/yy/zz Date of production
l Display only
l xx = day, yy = month, zz = year
C0207 DL info 1 Download info 1
l Display only
C0208 DL info 2 Download info 2
l Display only
C0209 DL info 3 Download info 3
l Display only
C0220 NSET Tir add 2.00 0.00 {0.01 s} 9999.90 Acceleration time T
ir
for additional
setpoint, function block NSET
l The acceleration time refers to
a speed variation of 0 ... C0011
See System
Manual
(extension)
C0221 NSET Tif add 2.00 0.00 {0.01 s} 9999.90 Deceleration time T
if
for
additional setpoint, function block
NSET
l The deceleration time refers to
a speed variation of C0011 ... 0
C0222 PCTRL Vp 1.0 0.1 {0.1 } 500.0 Gain V
p
, function block PCTRL1
See System
Manual
(extension)
C0223 PCTRL1 Tn 400 20 {1 ms} 99999 Integral action component T
n
,
function block PCTRL1
l C0223 = 99999 ms: no integral
action component
C0224 PCTRL1 Kd 0.0 0.0 {0.1 } 5.0 Differential component K
d
,
function block PCTRL1
C0234 damp value 20 −100 {1 %} 100 Influence of the oscillation
damping, function block MCTRL
l Minimising a tendency to
oscillation of the drive
l Influences the tendency to
oscillation of the drive
l When C0025 >1 and C0006 = 1,
C0234 is set to 0
8.2−25
8.2−40

Table of Contents