Configuration
Code table
8
8.5
8.5−44
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0738 Sampling
period
3
3 1 ms
Oscilloscope function
l Time base
See System
Manual
(extension)
4 2 ms
5 5 ms
6 10 ms
7 20 ms
8 50 ms
9 100 ms
10 200 ms
11 500 ms
12 1 s
13 2 s
14 5 s
15 10 s
16 20 s
17 50 s
18 1 min
19 2 min
20 5 min
21 10 min
C0739 Number of
channels
4 1 {1} 4 Function block OSZ
l Switching on/off the channels
1 = channel 1
2 = channel 1 + 2
3 = channel 1 ... 3
4 = channel 1 ... 4
See System
Manual
(extension)
C0740 0 Oscilloscope function
l Reading data memory
1 Read start
position
0 0 {1} 65535 l Provides a pointed access to a
storage block
2 Enable/inhibit
data reading
0
0 No data reading
1 Data reading
C0741 STATUS 0 1000000000
Function block OSZ
l Read only
See System
Manual
(extension)
1 Version
2 Memory size
3 Data width
4 Number of
channels
C0742 Data block
length
8 0 {1} 65536 Function block OSZ
C0743 Read data
block length
(OSZ)
0 65535 Function block OSZ
l Read only
l Reading an 8 byte data block
C0744 Memory depth 3
0 512 measured values
Oscilloscope function
l Adapt memory capacity to the
measurement task
1 1024 measured values
2 1536 measured values
3 2048 measured values
4 3072 measured values
5 4096 measured values
6 8192 measured values