Configuration
Code table
8
8.5
8.5−52
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0838
Selection list 2 Configuration of digital input
signals, function block OR5
See System
Manual
(extension)
1 CFG: IN 1000 FIXED0 OR5−IN1
2 CFG: IN 1000 FIXED0 OR5−IN2
3 CFG: IN 1000 FIXED0 OR5−IN3
C0839 0 1 Function block OR5
l Display of the signals linked in
C0838
1 DIS: IN OR5−IN1
2 DIS: IN OR5−IN2
3 DIS: IN OR5−IN3
C0840
CFG: IN 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block NOT1
See System
Manual
(extension)
C0841 DIS: IN 0 1 Function block NOT1
l Display of the signal linked in
C0841
C0842
CFG: IN 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block NOT2
See System
Manual
(extension)
C0843 DIS: IN 0 1 Function block NOT2
l Display of the signal linked in
C0842
C0844
CFG: IN 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block NOT3
See System
Manual
(extension)
C0845 DIS: IN 0 1 Function block NOT3
l Display of the signal linked in
C0844
C0846
CFG: IN 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block NOT4
See System
Manual
(extension)
C0847 DIS: IN 0 1 Function block NOT4
l Display of the signal linked in
C0846
C0848
CFG: IN 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block NOT5
See System
Manual
(extension)
C0849 DIS: IN 0 1 Function block NOT5
l Display of the signal linked in
C0848
C0850
Selection list 1 Configuration of analog input
signals, function block AIF−OUT
See System
Manual
(extension)
1 CFG: OUT.W1 1000 FIXED0% Process output word 1
l 100% = 16384
l Signal is output via byte 3 and
byte 4 to X1
2 CFG: OUT.W2 1000 FIXED0% Process output word 2
l 100% = 16384
3 CFG: OUT.W3 1000 FIXED0% Process output word 3
l 100% = 16384
C0851
CFG: OUT.D1 1000 FIXED0INC Selection list 3 Configuration of phase input
signal, function block AIF
l 32−bit phase signal

Table of Contents