EasyManua.ls Logo

Lenze 9300 Series - Page 342

Lenze 9300 Series
458 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
Code table
8
8.5
8.5−54
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0860
Selection list 1 Configuration of analog input
signals, function block CAN−OUT
See System
Manual
(extension)
1 CFG: OUT1.W1 1000 FIXED0%
CAN−OUT1
2 CFG: OUT1.W2 1000 FIXED0%
3 CFG: OUT1.W3 1000 FIXED0%
4 CFG: OUT2.W1 1000 FIXED0%
5 CFG: OUT2.W2 1000 FIXED0%
CAN−OUT2
6 CFG: OUT2.W3 1000 FIXED0%
7 CFG: OUT2.W4 1000 FIXED0%
8 CFG: OUT3.W1 1000 FIXED0%
CAN−OUT3
9 CFG: OUT3.W2 1000 FIXED0%
10 CFG: OUT3.W3 1000 FIXED0%
11 CFG: OUT3.W4 1000 FIXED0%
C0861
Selection list 3 Configuration of input signals,
function block CAN−OUT
1 CFG: OUT1.D1 1000 FIXED0INC CAN−OUT1
2 CFG: OUT2.D1 1000 FIXED0INC CAN−OUT2
3 CFG: OUT3.D1 1000 FIXED0INC CAN−OUT3
C0863 0 FFFF Process input words, function
block CAN−IN
l Read only
l Bit 0 ... bit 15 (via byte 5 and
byte 6)
l Bit 16 ... bit 31 (via byte 7 and
byte 8)
See System
Manual
(extension)
1 DIS: IN1 dig0 CAN−IN1, bit 0 ... bit 15
2 DIS: IN1 dig16 CAN−IN1, bit 16 ... bit 31
3 DIS: IN2 dig0 CAN−IN2, bit 0 ... bit 15
4 DIS: IN2 dig16 CAN−IN2, bit 16 ... bit 31
5 DIS: IN3 dig0 CAN−IN3, bit 0 ... bit 15
6 DIS: IN3 dig16 CAN−IN3, bit 16 ... bit 31
C0864 Output of the signal type,
function block CAN−OUT
See System
Manual
(extension)
1 TYPEOUT1.W2 0 0 analog Analog signal CAN−OUTx.Wx (C0860) is output
to X4
2 TYPEOUT2.W1 0 1 digital 0−15 Digital signal
bit 0 ... bit 15
FDO−00 ... FDO−15 (LOW word,
C0116/1 ... C0116/15) are output
to X4
3 TypeOUT3.W1 0 2 low phase Low phase CAN−OUTx.D1 (LOW word, C0861)
is output to X4
C0865 Output of the signal type,
function block CAN−OUT
1 TYPEOUT1.W3 0 0 analog Analog signal CAN−OUTx.Wx (C0860) is output
to X4
2 TYPEOUT2.W2 0 1 digital 16−31 Digital signal
bit 16 ... bit 31
FDO−16 ... FDO−31 (HIGH word,
C0116/16 ... C0116/31) are output
to X1
3 TYPEOUT3.W2 0 2 high phase High phase CAN−OUTx.D1 (HIGH word, C0861)
is output to X4

Table of Contents

Other manuals for Lenze 9300 Series

Related product manuals