Configuration
Code table
8
8.5
8.5−63
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1160
Selection list 1 Configuration of analog input
signals, function block ASW3
See System
Manual
(extension)
1 CFG: IN 1000 FIXED0% ASW3−IN1
2 CFG: IN 1000 FIXED0% ASW3−IN2
C1161
CFG: SET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block ASW3
l LOW: signal at ASW3−IN1 is
output to ASW3−OUT
l HIGH: signal at ASW3−IN2 is
output to ASW3−OUT
C1162 −199.99 {0.01 %} 199.99 Function block ASW3
l Display of the signals linked in
C1060
1 DIS: IN ASW3−IN1
2 DIS: IN ASW3−IN2
C1163 DIS: SET Function block ASW3
l Display of the signal linked in
C1061
C1190 Motor PTC
selection
0
Temperature characteristic for PTC
thermistors
l Selection of the characteristic
for PTC thermistors at X7 or X8
for detecting the motor
temperature
6.6−10
0 Standard Characteristic for PTC thermistors
in Lenze motors
1 Characteristic Characteristic for
application−specific PTC
thermistors
C1191 Temperature
characteristic
0 {1 °C} 255 Temperature range for PTC
thermistors
l Define temperature points on
the characteristic for PTC
thermistors
1 Temperature 1 100 Temperature point 1
2 Temperature 2 150 Temperature point 2
C1192 Resistance
characteristic
0 {1 W} 3000 Resistance characteristic for PTC
thermistors
l Define resistance points on the
characteristic for PTC
thermistors
1 Resistance 1 1670 Resistance point 1
2 Resistance 2 2225 Resistance point 2
C1300
N−motor/
Dmax
300 −32767 {1 rpm} 32767 Motor speed at D
max
, function
block DCALC1
l Nominal speed of the winding
drive
8.2−1
C1301
N−line max 3000 1 {1 rpm} 32767 Maximum line speed, function
block DCALC1
l Nominal speed of the line drive
C1302 calc cycle 0.1 0.1 {0.1 rev} 100.0 Calculation cycle, function block
DCALC1
8.2−1
C1303 time const 0.10 0.01 {0.01 s} 50.00 Filter time constant, function
block DCALC1