Configuration
Code table
8
8.5
8.5−66
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1341
Selection list 2 Configuration of digital input
signals, function block PCTRL2
See System
Manual
(extension)
1 CFG: RFG−LOAD 1000 FIXED0 l HIGH = function of
PCTRL2−RFG−SET is active
2 CFG: I−OFF 1000 FIXED0 l HIGH = Switches of integral
action component
l LOW = switches on integral
action component
3 CFG: INACT 1000 FIXED0 l HIGH = deactivates process
controller
4 CFG: OVERLAY 1000 FIXED0 l HIGH = Shows influence
l LOW = hides influence
C1344 −199.99 {0.01 %} 199.99
Function block PCTRL2
l Display of the signals linked in
C1340
See System
Manual
(extension)
1 DIS: RFG−SET
2 DIS: SET
3 DIS: ACT
4 DIS: INFL
C1345 0 1
Function block PCTRL2
l Display of the signals linked in
C1341
1 DIS: RFG−LOAD
2 DIS: I−OFF
3 DIS: INACT
4 DIS: OVERLAY
C1350 INT1 function 0
Function selection, function block
INT1
See System
Manual
(extension)
0 PHI >= REF If INT1−IN ³ INT1−REF, INT1−DOUT
is set to HIGH
1 |PHI| >= |REF| If |INT1−IN| ³ |INT1−REF|,
INT1−DOUT is set to HIGH
C1351 INT1 scaling 65536
00
65536 {1} 1000000000
Scaling factor, function block INT1
INT1 * AOUT[%] +
INT1 * IN[inc]
C1351
@ 100%
C1354
CFG: REF 1000 FIXED0INC Selection list 3 Input signal configuration
l Reference value
See System
Manual
(extension)
C1355
CFG: IN 1000 FIXEDPHI−0 Selection list 4 Configuration of input signal,
function block INT1
l Angle of rotation
C1356
CFG: RESET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block INT1
l HIGH = Sets the integrator to 0
C1357 DIS: REF −2000000000 {1 inc} 2000000000 Function block INT1
l Display of the signal linked in
C13554
See System
Manual
(extension)
C1358 DIS: IN −32767 {1 rpm} 32767 Function block INT1
l Display of the signal linked in
C1355
C1359 DIS: RESET 0 1 Function block INT1
l Display of the signal linked in
C1356
C1360 INT2 function 0
Function selection, function block
INT2
See System
Manual
(extension)
0 PHI >= REF If INT2−IN ³ INT2−REF, INT2−DOUT
is set to HIGH
1 |PHI| >= |REF| If |INT2−IN| ³ |INT2−REF|,
INT2−DOUT is set to HIGH
C1361 INT2 scaling 65536
00
65536 {1} 1000000000
Scaling factor, function block INT2
INT2 * AOUT[%] +
INT2 * IN[inc]
C1361
@ 100%