Appendix
10-38
BA9300POS EN 2.3
Code IMPORTANTPossible settingsLCDCode IMPORTANT
ChoiceLenze
LCD
[C1126]
+0
1000 FIXED0INC
Å
Selection list 3 Configuration input 3 of SYNC1
^
10-58
C1127
+0
g
-2147483647 {1} 2147483647 Input signal 1 of
SYNC1
C1128
+0
g
-2147483647 {1} 2147483647 Input signal 2 of
SYNC1
C1129
+0
g
-2147483647 {1} 2147483647 Input signal 3 of
SYNC1
[C1130]
1
2
07/
&'0
1000
1000
50 {1} 25104
Å
Selection list 1
CFG: CONVPHPH2-NUM
^
10-58
[C1131]
#%6
1000 51 {1} 25132
Å
Selection list 2
CFG: CONVPHPH2-ACT
^
10-58
[C1132]
+0
1000 50 {1} 25104
Å
Selection list 3
CFG: CONVPHPH2-IN
^
10-58
C1135
1
2
07/
&'0
g
-32767 {1} 32767
DIS: CONVPHPH2-..
C1136
#%6
g
01DIS: CONVPHPH2-ACT
C1137
+0
g
-2147483647 {1 incr} 2147483647 DIS: CONVPHPH2-IN
[C1160]
1
2
+0
+0
1000
1000
Å
Selection list 1
FIXED0%
FIXED0%
Configuration analog inputs of ASW3
^
10-58
[C1161]
5'6
1000 FIXED0
Å
Selection list 2 Configuration digital input of ASW3
^
10-58
C1162
1
2
+0
+0
g
-199.99 {0.01 %} 199.99 Analog input signals of ASW3
C1163
5'6
g
Digital input signal of ASW3
[C1165]
1
2
+0
+0
1000
1000
Å
Selection list 1
FIXED0%
FIXED0%
Configuration analog inputs of ASW4
^
10-58
[C1166]
5'6
1000 FIXED0
Å
Selection list 2 Configuration digital input of ASW4
^
10-58
C1167
1
2
+0
+0
g
-199.99 {0.01 %} 199.99
Analog input signals of ASW4
C1168
5'6
g
Digital input signal of ASW4
C1180
+&D0 /M&D
Mode: control parameter identification
0 0inactive not active
1calculate Calculate control parameters from data set
2 Identify Identify only parameters
3 ident&calc. Calculate only parameters for control system
and control
C1181
H& 5 C D
Status: controller ident.
^
5-27
g
0inactive Not active
1 busy busy
2 Error: no calculation Fault
^
5-29
3 Error: no identification
4 Error: C0057 small
5 Error: n < > 0
6 Error: RSP
7 Error: C1185 big
8 Error: overtime
9 Error: bad condition