Appendix
10-40
BA9300POS EN 2.3
Code IMPORTANTPossible settingsLCDCode IMPORTANT
ChoiceLenze
LCD
C1211
5 C4 25 0M
1 1 {1} 32 Start -PS no.
• Program set no. at which the positioning
program is processed after the edge at
the ”PRG-START” input.
C1212
# 25 0M
g
0 Prog. end
1PS01
2PS02
3PS03
...
31 PS 31
32 PS 32
Actual PS no.
• Display of the momentary program set
no. or operating mode.
C1213
4DE LM&D
0 0 + home
1 -home
2 + LIM,-home
3 -LIM,+ home
4 + MARK,-home
5 -MARK,+ home
6+MARK,+TP
7-MARK,-TP
8+TP
9-TP
10 + LIM,-TP
11 -LIM,+TP
Homing mode
• Mode for homing (valid for manual mode
and program homing).
C1214
4DE 62+0N7
4 1TP-IN=E01
2TP-IN=E02
3TP-IN=E03
4TP-IN=E04
Homing touch probe
• Selection of the touch probe input ter-
minal for homing acc. to modes 6...9.
When using an incremental encoder, the
TP input E04 is particularly suitable.
C1215
1
...
4
6264C0P
6264C0P
0
...
0
0 + slope
1 -slope
TP input edge
• Selection of the edge for the touch probe
input terminals (valid for homing acc. to
modes 6 to 9, TP positioning, TP storing).
C1216
84DE C HQ
0 0inactive
1active
Activation of 2nd homing speed
C1218
1
2
(MK MKD4C0 D
(MK
MKD4C0 D
4.0000
1.0000
0 {0.0001 units} 214000 Contouring error tolerance
C1220
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
2156#4)'6
2155'6215
215#%6215
#
EMKKMR'44
#%6215 C
P
4'(/#4- +LN
#
GMLD MEEP
#
GMLD NMP
#
9CT
#
%
#
%
#
%
#
%
#
80M4L
#
#0M4L
g
-214000 {0.0001 units} 214000
1 = Current position target
2 = Current position setpoint
3 = Current position
4 = Current contouring error
5 = Read absolute value
6 = Distance REF-MARK to zero pulse
7 = Current reference offset
8 = Current reference position
9 = Distance to be traversed
10 - 13 = Effective internal code value:
C1223/C1224/C1240/C125010
(internal limitation possible: see chapter:
Troubleshooting, “Message P18”)
14 - 15 = Internal fault analysis value