13 Error messages
13.2 Possible causes and remedies
96
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
 
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 
EtherCAT: Sync telegram failure [0x00c88700]
Response (Lenze setting printed in bold) Setting: C13880/2 / C14880/2 ( Configurable response)
 None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information
Cause Remedy
• EtherCAT-Sync0 signal has failed.
• PDO sent or received too late as the instant of 
transmission of the EtherCAT frame by the master 
jitters too much.
• Check EtherCAT master configuration if the DC mode 
has been set.
• Restart EtherCAT configuration.
• Postpone PDO instant of reception via the user shift 
time.
• Increase sync error counter monitoring limit 
(0x10F1.2).