9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Selection of master value source and output
30 L EDS94TA10040xxxx EN 1.1 - 10/2008
4.4.1 Master value source: Virtual master
If the "Virtual master" is selected as master value source, the master value is created in the
TA and transmitted via a bus system or the digital frequency output to the other slave
drives.
r Parameter setting: Tab Application parameters dialog level Overview Virtual
master
r Configuration: Tab FB editor FB Virtual_Master
Parameter Lenze setting
Value Unit
C03565 Operating mode Continuous operation
C03566 STOP position 0.0000 unit
C03567 START position 0.0000 unit
C03568/1 1. master speed 360.0000 unit/t
C03568/2 2. master speed 180.0000 unit/t
C03569/1 Speed - inching - CW rotation 900.0000 unit/t
C03569/2 Speed - inching - CCW rotation 900.0000 unit/t
C03570/1 Inching ramp 5.000 s
C03570/2 Ramp - single cycle/continuous operation 5.000 s
C03570/3 STOP ramp 0.5000 s
Control/setpoint inputs of the function Signal configuration
Lenze setting Control/setpoint input (Multiplexer parameters)
FALSE VMas master shaft STOP1 C03058/1
C03016 Activate master function C03058/3
C03017 VMas inching positive C03058/4
C03018 VMas inching negative C03058/5
FALSE VMas start single cycle C03058/6
FALSE VMas start continuous operation C03058/7
FALSE VMas 2. master speed C03058/8
0 VMaster handwheel C03056