EasyManua.ls Logo

Lenze 9400

Lenze 9400
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EDS94TA10040xxxx EN 1.1 - 10/2008 L 33
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Synchronism" mode"
4.5.1 Master value processing
[4-5] "Master value processing" function in the signal flow (schematic diagram)
r Parameter setting: Tab Application parameters dialog level Overview Synchronism
Master value processing
r Configuration: Tab FB editor FB ElectricalShaftVal
n Master value
oMaster value with stretch factor
M
v
Slave
Real master/
Virtual master
v
t
Dv
C03006 = 0

Parameter Lenze setting
Value Unit
C03587 Master value - unit
C03000 Stretch factor - numerator 1000000000
C03001 Stretch factor - denominator 1000000000
C03025 Master value - direction of rotation Not inverted
C03034 Starting position 0.0000 unit
C03938 Cycle (register) 360.0000 unit
C03672 Master value with stretch factor - unit
Setpoint inputs of the function Signal configuration
Lenze setting Setpoint input (Multiplexer parameters)
DIGIN CINH Set starting position of master shaft C03058/11
C03034 Master shaft starting position C03053/1
C03000 Stretch factor - numerator C03050/1
C03001 Stretch factor - denominator C03050/2

Table of Contents

Other manuals for Lenze 9400

Related product manuals