EasyManua.ls Logo

Lenze 9400 - Displayclutchspeed

Lenze 9400
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
58 L EDS94TA10040xxxx EN 1.1 - 10/2008
4.14.7 DisplayClutchSpeed
C03721 -214748.3647 unit/t 214748.3647 Speed X at the output
•Read only
Is generated from the speed
signal dnXSpeedOut_s.
C03722 -214748.3647 unit/t 214748.3647 Speed Y at the output
•Read only
Is generated from the speed
signal dnYSpeedOut_s.
C03723 -214748.3647 unit 214748.3647 Position X at the output
Display of output signal
dnXActPos_p in real unit of the
machine.
C03724 -214748.3647 214748.3647 Status
Display of the bit-coded output
signal dnState.
Parameter Possible settings Information
Is an instance of Function
L_LdExtrapolate Extrapolation of current master shaft position in the register for speed display.
Parameter Possible settings Information
C03705 1 127 Number of extrapolation cycles
•Initialisation: 1
C03706/1 String of digits Position unit
•Read only
C03706/2 String of digits Speed unit
•Read only
C03712 -214748.3647 unit/t 214748.3647 Speed at the output
•Read only
Is generated from the speed
signal dnSpeedOut_s.
C03713 -214748.3647 unit 214748.3647 Position at the output
•Display of the dnPosOut_p output
signal in the real unit of the
machine.
C03714 Extrapolation cycles > selected value
•Read only
0No (OK)
1Yes (error)