EDS94TA10040xxxx EN 1.1 - 10/2008 L 41
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Homing" mode
4.6 "Homing" mode
In the "Homing" mode (C03006 = "2") the drive is decoupled from the electrical shaft and
the basic function "Homing" is enabled:
[4-11] "Homing" mode (schematic diagram)
r Parameter setting: Tab Application parameters dialog level Overview Homing
v
t
LS_ManualJog
n
t
è
ç
n
t
LS_Positioner
0-100 100 200
LS_Homing
C03006 = 2
t
M
Slave
Parameter Lenze setting
Value Unit
C02528 Traversing range Modulo
C02640 Homing mode Set home pos. directly
C02642 Home position 0.0000 unit
C02643 Homing: Target position 0.0000 unit
C02644 Homing: Speed 1 360.0000 unit/s
C02645 Homing: Acceleration 1 720.0000 unit/s
2
C02646 Homing: Speed 2 0.0000 unit/s
C02647 Homing: Acceleration 2 360.0000 unit/s
2
C02648 Homing: S-ramp time 100 ms
C02649 Homing: Torque limit 10.00 %
C02650 Homing: Blocking time 1.000 s
C02652 Ref. pos. after mains switching Delete
C02653 Max. rot. ang. aft. mns. swtch. 180 °
C03011 Set home position Inactive
C03012 Home position 0.0000 unit
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Start homing C03160/2
DIGIN 2 Home mark C03160/3
C03011 Set home position C03160/4
C03012 Home position C03163
FALSE Reset home position C03160/5

Table of Contents