9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
70 L EDS94TA10040xxxx EN 1.1 - 10/2008
4.14.21 OverrideProfile
C03559 Extrapolation cycles > selected value
•Read only
0No (OK)
1Yes (error)
Parameter Possible settings Information
Is an instance of Function
L_PosProfileTable Storage and management of up to four travel profiles for the "positioning" mode.
"Positioning" mode"
(C 43)
Parameter Possible settings Information
C03970/1...4
(subcode 1 ... 4 profile no. 1 ... 4)
Positioning mode
For absolute positioning, the
home position must be known.
1Absolute
2Absolute TP
5Relative
6 Relative TP
7 Speed
8 Speed TP
11 Absolute CW
12 Absolute CW TP
13 Absolute CCW
14 Absolute CCW TP
15 Absolute ShortestWay
16 Absolute ShortestWay TP
C03971/1...4
(subcode 1 ... 4 profile no. 1 ... 4)
-214748.3647 unit 214748.3647 Position
C03972/1...4
(subcode 1 ... 4 profile no. 1 ... 4)
-214748.3647 unit/t 214748.3647 Speed
C03973/1...4
(subcode 1 ... 4 profile no. 1 ... 4)
0.0000 unit/t
2
214748.3647 Acceleration
C03974/1...4
(subcode 1 ... 4 profile no. 1 ... 4)
0.0000 unit/t
2
214748.3647 Deceleration
C03975/1...4
(subcode 1 ... 4 profile no. 1 ... 4)
0.0000 s 214748.3647 S-ramp time
C03976/1...4
(subcode 1 ... 4 profile no. 1 ... 4)
TP sequence profile
Sequence profile for touch probe
residual path positioning.
0 No residual path positioning
1 Profile no. 1
... ...
4 Profile no. 4