EasyManua.ls Logo

Lenze 9400

Lenze 9400
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EDS94TA10040xxxx EN 1.1 - 10/2008 L 35
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Synchronism" mode"
TP profile parameters
r Parameter setting: Tab Application parameters dialog level Overview TP profile
parameters
r Configuration: Tab FB editor FB MarkSynchronizationShaft
TP interface
r Parameter setting: Tab Application parameters dialog level Overview TP interface
Parameter Lenze setting
Value Unit
C03620 Positioning mode 0
C03621 Deactivation mode 0
C03623/1 Positive speed 3600.0000 unit/t
C03623/2 Negative speed 3600.0000 unit/t
C03626/1 Acceleration ramp 1.000 s
C03626/2 Deceleration ramp 1.000 s
C03626/3 Stop ramp 1.000 s
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Activate master value TP correction C03058/12
Parameter Lenze setting
Value Unit
C02810/3 Signal delay TP3 0 μs
C03022 Edge evaluation of positive edge TRUE
C03024 Edge evaluation of negative edge FALSE