EasyManua.ls Logo

Lenze 9400 - Contact Function Test − Error−Free Input Signals; Contact Function Test − Faulty Input Signals

Lenze 9400
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety engineering
Device modules
Safe inputs
1
34
EDS94AYAE EN 6.0
A
B
C
D
SSP94SM358_1
Fig. 1−6 Contact function test − error−free input signals
A
B
C
D
AIE

SSP94SM358_2
Fig. 1−7 Contact function test − faulty input signals
A, B Safe input, channel A and channel B
C Internal valuation of the safe input
D Discrepancy monitoring
AIE Fault acknowledgement
Discrepancy monitoring active
Discrepancy monitoring − time−out
Fault acknowledgement impermissible
Fault acknowledgement permissible