Safety engineering
Safety functions
Safely limited speed
1
73
EDS94AYAE EN 6.0
Index:Data type:Name:Parameter:
C15333 SLS: Permissible direction of movement
UNSIGNED_8 9242
d
= 241A
h
Permissible direction of movement during SLS monitoring
Selection list
(Lenze setting printed in bold) Information
0 Both directions enabled
1 Positive direction enabled
2 Negative direction enabled
Subcodes Information
C15333/1 SLS1: Permissible direction of movement (from SM301
V1.3)
C15333/2 SLS2: Permissible direction of movement (from SM301
V1.3)
C15333/3 SLS3: Permissible direction of movement (from SM301
V1.3)
C15333/4 SLS4: Permissible direction of movement (from SM301
V1.3)
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer
C15350 SLS, SMS: Max. response time
UNSIGNED_16 9225
d
= 2409
h
Maximum time after an exceeded speed has been detected, after which the speed must be below the limit
again.
Setting range
(min. value | unit | max. value) Information
0 MS 30000 Lenze: 0, increment: 2 ms
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer
1.3.9.2 Activation
How to activate the function:
ƒ "OFF state" at a safe input, the function of which has been assigned by parameter
setting.
ƒ Via a safety bus data telegram with corresponding content.
1.3.9.3 Fault analysis
The fault analysis is described with the SMS function ( 69).