Safety engineering
Safety functions
Safely limited speed
1
72
EDS94AYAE EN 6.0
Codes
Parameter: Name: Data type: Index:
C15330 SLS: Limited speed Nlim
UNSIGNED_16 9245
d
= 241D
h
Setting of the limited speed
Setting range
(min. value | unit | max. value) Information
0 rpm 16000 Lenze: 0
Subcodes Information
C15330/1 SLS1: Limited speed Nlim1
C15330/2 SLS2: Limited speed Nlim2
(As of SM301 V1.1)
C15330/3 SLS3: Limited speed Nlim3
(As of SM301 V1.1)
C15330/4 SLS4: Limited speed Nlim4
(As of SM301 V1.1)
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer
C15331 SLS: Braking time Nlim
UNSIGNED_16 9244
d
= 241C
h
Safely monitored time for braking the drive to the limited speed set in C15330.
Setting range
(min. value | unit | max. value) Information
0 MS 30000 Lenze: 0, increment: 2 ms
Subcodes Information
C15331/1 SLS1: Braking time Nlim1
C15331/2 SLS2: Braking time Nlim2 (as of SM301 V1.1)
C15331/3 SLS3: Braking time Nlim3 (as of SM301 V1.1)
C15331/4 SLS4: Braking time Nlim4 (as of SM301 V1.1)
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer
C15332 SLS: Response (n>Nlim)
UNSIGNED_8 9243
d
= 241B
h
Response in the safety module to the exceeding of the limited speed
Selection list
(Lenze setting bold) Information
0 STO Safe torque off
1 SS1 Safe stop 1
2 SS2 Safe stop 2
Subcodes Information
C15332/1 SLS1: Response (n>Nlim1)
C15332/2 SLS2: Response (n>Nlim2) (as of SM301 V1.1)
C15332/3 SLS3: Response (n>Nlim3) (as of SM301 V1.1)
C15332/4 SLS4: Response (n>Nlim4) (as of SM301 V1.1)
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer