Safety engineering
Safety functions
Safe stop 1
1
58
EDS94AYAE EN 6.0
Codes
Parameter: Name: Data type: Index:
C15300 Restart behaviour
UNSIGNED_8 9275
d
= 243B
h
Behaviour for restart after functions have been cancelled
Selection list
(Lenze setting bold) Information
0 Acknowledged restart
1 Automatic restart
Subcodes Information
C15300/1 Restart - STO, SS1
C15300/2 Restart - SS2, SOS
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer
C15305 SS1, SS2: Stopping time
UNSIGNED_16 9270
d
= 2436
h
Stopping time for the SS1 and SS2 safety functions
Setting range
(min. value | unit | max. value) Information
0 MS 30000 Lenze: 0, increment: 2 ms
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer
C15306 SS1 mode
UNSIGNED_8 9269
d
= 2435
h
Selection list (Lenze setting bold) Information
0 STO after stopping time
(From SM301 V1.3)
1 STO at n = 0
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer
C15307 SS1: Deceleration STO after n=0
UNSIGNED_16 9268
d
= 2434
h
Display area (min. value | unit | max. value) Information
0 ms 30000 Lenze: 0, increment: 2 ms (From SM301 V1.3)
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer
C15310 Tolerance window (n=0)
INTEGER_16 9265
d
= 2431
h
Safely monitored tolerance window for zero speed
Setting range
(min. value | unit | max. value) Information
0 rpm 16000 Lenze: 0
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer