Safety engineering
Appendix
Module internal codes
1
113
EDS94AYAE EN 6.0
Index:Data type:Name:Parameter:
C15003 Command status
UNSIGNED_16 9572
d
= 2564
h
Status of the current command.
l In high byte the command is repeated.
l In low byte the status is displayed:
0x00: no command
0x01: command executed
0x02: password invalid
0x03: command in process
0x04: command unknown
0x05: command error
Display area
(min. value | unit | max. value) Information
0 2309
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15010 Parameter set status
UNSIGNED_8 9565
d
= 255D
h
Status of the parameter set
Selection list
(read only) Information
0 No parameter set
1 Parameter set valid
2 Read error − memory module
3 Parameter set dissimilar
4 CRC error
5 Version error
6 Format error
7 Plausibility error
8 Assignment error
9 Local read error
10 Communication error GG
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15011 Parameter CRC
UNSIGNED_32 9564
d
= 255C
h
Parameter checksum (CRC = Cyclic Redundancy Code)
Display area
(min. value | unit | max. value) Information
0 4294967295
Subcodes Information
C15011/1 CRC safety module
C15011/2 CRC memory module
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15013 Time for parameter set creation
UNSIGNED_64 9562
d
= 255A
h
Time of parameter set creation
Display area
(min. value | unit | max. value) Information
0 1844674407370
96E+19
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15014 Time − RTC parameter setting
VISIBLE_STRING 9561
d
= 2559
h
Time of parameter set transfer from the memory module as a value of the real−time clock (RTC).
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15015 Time sec. parameter setting
UNSIGNED_32 9560
d
= 2558
h
Time of parameter set transfer from the memory module as a value of the power−on time meter from the
controller.
Display area
(min. value | unit | max. value) Information
0 S 4294967295
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer