Safety engineering
Appendix
Module internal codes
1
114
EDS94AYAE EN 6.0
Index:Data type:Name:Parameter:
C15016 Parameter set version
UNSIGNED_8 9559
d
= 2557
h
Display of the parameter set version in the safety module.
Selection list
(read only) Information
0 No current parameter set
(From SM301 V1.1)
1 Parameter set V1.0
2 Parameter set V1.1
3 Parameter set V1.2 (From SM301 V1.2)
4 Parameter set V1.3 (From SM301 V1.3)
5 Parameter set V1.4 (From SM301 V1.4)
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15017 Stored module ID
UNSIGNED_16 9558
d
= 2556
h
Module ID stored in the safety module
Display area
(min. value | unit | max. value) Information
0 65535
(As of SM301 V1.2)
Default setting (invalid ID): 0
Stored ID defective: 65535
þ Read access o Write access o Controller inhibit o PLC-STOP o No transfer
C15030 SD-In sensor type
UNSIGNED_8 9545
d
= 2549
h
Configuration of the sensor types which are connected to the safe inputs.
Selection list
(Lenze setting bold) Information
0 Input deactivated
1 Passive sensor
2 Active sensor
Subcodes Information
C15030/1 SD-In1 sensor type
C15030/2 SD-In2 sensor type
C15030/3 SD-In3 sensor type
C15030/4 SD-In4 sensor type
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer
C15031 SD-In sensor function
UNSIGNED_8 9544
d
= 2548
h
Function configuration of the safe inputs.
l The "operation mode selector" and "enable switch" functions may only be assigned to one of the four safe
inputs.
Selection list
(Lenze setting printed in bold) Information
0 Free assignment Safety function set in C15032
1 Emergency stop Safe stop emergency function (SSE)
2 Operation mode selector Safe operation mode selector (OMS)
3 Enable switch Safe enable switch (ES)
Subcodes Information
C15031/1 SD-In1 sensor function
C15031/2 SD-In2 sensor function
C15031/3 SD-In3 sensor function
C15031/4 SD-In4 sensor function
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer