Safety engineering
Safe bus interfaces
PROFIsafe connection
1
94
EDS94AYAE EN 6.0
Codes
Parameter: Name: Data type: Index:
C15113 S-Bus: Filter control data
BITFIELD_32 9462
d
= 24F6
h
Bit coded selection of the active bit positions in the safety bus control data
Value is bit coded:
Information
Bit 0 STO Safe torque off
Bit 1 SS1 Safe stop 1
Bit 2 SS2 Safe stop 2
Bit 3 SLS1 Safely limited speed 1
Bit 4 SLS2 Safely limited speed 2
(From SM301 V1.1)
Bit 5 SLS3 Safely limited speed 3
(From SM301 V1.1)
Bit 6 SLS4 Safely limited speed 4
(From SM301 V1.1)
Bit 7 SDIpos Safe positive direction
(From SM301 V1.3)
Bit 8 SDIneg Safe negative direction
(From SM301 V1.3)
Bit 9 ES Safe enable switch
Bit 10 Reserved
Bit 11 OMS Safe operation mode selector
Bit 12 Reserved
...
Bit 15 Reserved
Bit 16 PS_AIS Restart acknowledgement via safety bus
Bit 17 PS_AIE Fault acknowledgement via safety bus
Bit 18 Reserved
...
Bit 22 Reserved
Bit 23 SSE Emergency stop function
Bit 24 SD−Out1 Safe output
Bit 25 Reserved
...
Bit 31 Reserved
þ Read access Write access o Controller inhibit o PLC-STOP o No transfer