4 Technical data
4.1 General data and operating conditions
Hardware manual for Inverter Drives 8400 motec
Here you will find the ambient conditions and information on the electromagnetic
compatibility (EMC) that also apply to the Communication Unit.
Range Values
Order designation E84DGFCGxNx (EtherNet/IP)
E84DGFCGxJx (EtherNet/IP + Safety)
Communication profile EtherNet/IP
Standards / specifications Safety engineering: EN 954-1, EN 13849-1, IEC 61508
(up to safety category 4)
Interface for communication EtherNet/IP port 1: M12 socket, 5-pin, D-coded
EtherNet/IP port 2: M12 socket, 5-pin, D-coded
Network topology Tree, star, and line
Type of node Adapter (slave)
Number of nodes Max. 254 in the subnetwork
Max. cable length 100 m
Vendor ID 587 (0x24B), Lenze (’Lenze AC Tech’ in older Rockwell data)
Device type 2 (0x02), AC Drive
Product code 8440 (0x20F8)
Baud rate 10 Mbps
100 Mbps
Transmission mode Half duplex / full duplex
Switching method Store-and-forward / cut-through
Switch latency Approx. 125 μs at max. telegram length
External voltage supply U = 24 V DC (20 V - 0 % ... 29 V + 0 %)
•I
max
= 400 mA
Conformities, approvals CE
•UR / cUR
(see also hardware manual)