Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013 78
Diagnostics
LED status displays
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11 Diagnostics
EtherNet/IP communication can be diagnosed via the LEDs of the Communication Unit. Moreover,
the »Engineer« serves to show diagnostic information.
11.1 LED status displays
E84DG056
LED Colour / status Description
MS Green Red
Off Off CIP module status: "Nonexistent"
The Communication Unit is not supplied with voltage.
Off On
CIP module status: "Major Unrecoverable Fault"
The Communication Unit has an unrecoverable fault.
Off Blinking
CIP module status: "Major Recoverable Fault"
The Communication Unit has a recoverable fault.
On Off
CIP module status: "Operational"
The Communication Unit is working correctly.
Blinking Off
CIP module status: "Standby"
The Communication Unit has not been completely configured yet, or the
configuration is incorrect.
Blinking Blinking
CIP module status: "Device Self Testing"
The Communication Unit performs a self-test.
250 ms
250 ms
250 ms
250 ms
250 ms
250 ms