EasyManua.ls Logo

Lenze E84DGFCG Series - Page 98

Lenze E84DGFCG Series
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013 98
Parameter reference
Parameters of the Communication Unit
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13844
C13845
C13846
C13847
Parameter | Name:
C13844 | Beacon Times
Data type: UNSIGNED_32
Index: 10731 = 0x29EB
Display of the beacon times (μs)
Subcodes Info
C13844/1 Beacon interval
C13844/2 Beacon timeout
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13845 | Beacon Frames
Data type: UNSIGNED_32
Index: 10730 = 0x29EA
Display of beacon frame information
Subcodes Info
C13845/1 Beacon frames - port X31
C13845/2 Beacon frame error - port X31
C13845/3 Beacon frames - port X32
C13845/4 Beacon frame error - port X32
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13846 | Address Conflict Detection
Data type: UNSIGNED_8
Index: 10729 = 0x29E9
Activation of the address conflict detection (ACD)
(Instance attribute 10 (SelectAcd) in the TCP/IP Interface Object (245 / 0xF5)
( 126))
Changing this value requires a reset of the device ("power off/on" or "type 0 reset").
Selection list (Lenze setting printed in bold)
0 Deactivated
1Enable
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13847 | Active Conflict Detection State
Data type: UNSIGNED_8
Index: 10728 = 0x29E8
Display of the status of address conflict detection (ACD)
Selection list (read only)
0 Not conflicted
1 Conflicted
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT

Table of Contents