Commissioning
Operang Instrucons i510 protec 19
7.2.4 Extended terminal control
The following illustraon shows a more extensive wiring of the control
terminals (X3, X9 and X216) linked with the respecve parameters.
GND
AI1
AI2
AO1
10V
24V
DI1
DI2
DI3
DI4
DI5
GND
DO1
NO
COM
NC
U/I
*P400.02
Preset 01 (*P450.01)
*P400.04
*P400.13
bit 1 bit 0
0
0
1
1
1
1
Preset 02 (*P450.02)
Preset 03 (*P450.03)
*P400.18
*P400.19
*P420.02
*P420.01
24E
*P201.01
(configured AI1 as
standard setpoint)
Default seng
Start
Reset error
Mark direcon of rotaon
Acvate preset (bit 0)
Acvate preset (bit 1)
DO1 acvated at
Release brake
Relay acvated at
Ready for operaon
Analog input 1
24 V DC, 100 mA supply, reference for digital inputs
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Digital input 5
Digital output 1
GND for analog and digital signals
Relay NO contact
Relay common contact
Relay NC contact
Preset frequency values
*P430.01 (0 ... 10 V DC signal)
Analog input 2
*
Analog output 1
10 V DC supply for potenometer
P430.02 ... *P430.03
range [Hz]:
config.:
Oponal external 24-V-supply
GND for analog and digital signals
7.3 Keypad control
Acvatetemporarykeypadcontrol
1. Press the
key to acvate the keypad control.
2. Press the
key to conrm the keypad control.
Deacvatetemporarykeypadcontrol
1. Press the
key to deacvate the keypad control.
2. Press the
key to conrm the keypad control.
Acvatepermanentkeypadcontrol
If the keypad does not have a
key, the motor control is acvated via
the following parameters:
Set parameter P200.00 to 1.
Set parameter P201.01 to 1.
Set parameter P400.01 to 1.
Set parameter P400.02 to 1.
Use the
key to start the motor.
Start/control/stop motor with keypad
1. Press the
key to start the motor.
The keypad shows the motor speed.
2. Use the
key or the key to change the frequency setpoint.
3. Press the
key to stop the motor.
Changerotangdirecon
1. Press the
key.
2. Press the
key to conrm the reversal of rotang direcon.
7.4 Commissioning with the EASY Starter
Commissioning and diagnoscs can be carried out with the
EASY Starter engineering tool. hps://www.Lenze.com