Further documents
Operang Instrucons i510 protec28
8.4 LED status
LED “RDY” (blue) LED “ERR” (red) Status/meaning
o o No supply voltage
Mains voltage is switched on, inverter is
inialized
ashes
o Inverter is disabled, ready for operaon
ashes fast
Safe torque o (STO) acve, warning acve
ashes
o Inverter inhibited
ashes fast
Inverter disabled, warning acve
Inverter disabled, error acve
every 1.5 s on
Inverter disabled, no DC bus voltage
o Inverter enabled
o The motor rotates according to the specied
setpoint or quick stop acve
ashes fast
Inverter enabled, warning acve. The motor
rotates according to the specied setpoint or
quick stop acve
ashes
Inverter enabled, quick stop as response to fault
acve
9 Further documents
For certain tasks, informaon is available in further documents.
Document Contents/topics
Project planning document Fundamental informaon on project planning and ordering the product
Commissioning document Fundamental informaon for the installaon and commissioning of the
product
Mounng instrucons Fundamental informaon on mounng the product
The documents can be found online: hp://www.Lenze.com
10 Disposal
If pollutants are disposed o improperly, they may cause a lasng
damage to human health and the environment. Thus, electrical and
electronic equipment must be collected separately from unsorted
municipal waste so that it may be recycled or disposed of properly.
If available, put the components to the company internal disposal from
where it is passed on to specialized waste management companies.
It is also possible to return the components to the manufacturer. For this
purpose, please contact the customer service of the manufacturer.
More detailed informaon on disposal can be obtained from the
corresponding specialist rms and the competent authories.
The packaging of the component must be disposed of separately. Paper,
cardboard and plascs must be recycled.
11 Glossary
Abbreviaon Meaning
AIE Error acknowledgement (“Acknowledge In Error”)
OFF state Signal status of the safety sensor when it triggers or responds
QSP Quick stop