Motor mounting
Preparations
3
EDK82MV371 DE/EN/FR 6.0
89
L
Fig. 18
1a
1a
3.4 Nm
30 lb-in
1a
4×
M20 M16
2×
A
5mm
68mm
68mm
B
2
A
−12−8200mot053
Motor preparation:
l Remove terminal box seal and motor terminal board.
l If necessary, extend the motor cable.
Mount the carrier housing to the motor:
l If required, use the distance and wall mounting plate (2) and the terminal box seal .
l The mounting and fixing must ensure a permanently tight mechanical connection, for instance by using
serrated lock washers .
Perfect sealing is required to ensure enclosure IP65.
efesotomasyon.com - Lenze