Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17 102
13 Parameter reference
13.1 Parameters of the communication module
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13902
C13920
Parameter | Name:
C13902 | Firmware version
Data type: VISIBLE_STRING
Index: 10673
d
= 29B1
h
Display of the firmware version (string with a length of 5 bytes)
Example: "01.00"
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13920 | Display: DIP switch setting
Data type: UNSIGNED_8
Index: 10655
d
= 299F
h
Display of the current DIP switch setting
The displayed value corresponds to the sum of the individual DIP switch values 1 ... 64.
The active station address is displayed under C13864
.
Setting the station address
( 32)
Display area (min. value | unit | max. value)
0 255
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT