EasyManua.ls Logo

Lexicon LXP-5 - Troubleshooting; LXP-5 Signal Path Troubleshooting

Lexicon LXP-5
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LXP-5
Service
Manual
Performance
Verification
Since
Diagnostic
Tests
can
be
performed
without
opening
the
unit
they
Troubleshooting
should
generally
be
run
first.
This
greatly
reduces
repair
time,
as
a
problem
-
can
be
isolated
to
a
specific
circuit,
even
to
a
specific
1C
before
opening
the
unit.
The
following
presents
a
diagrammatic
version
of
the
recommended
trou¬
bleshooting
procedure
with
page
references.
NO
WET
AUDIO
SIGNAL
Run
Diagnostic
Tests
to
isolate
digital
hardware
problems:
ROM
test
2-6
Master
RAM
test
2-6
Master
Address
test
2-6
Master/Siave
WCS
tests
2-8
Individual
Slave
tests
2-7,
2-8
AUDIO
SIGNAL
PROBLEMS
NO
DRY
AUDIO
SIGNAL
Check
Power
Supplies
2-10,
3-3
Check
Power
Supplies
2-10,
3-3
>
r
r
Check
Clocks
and
timing
2-10
r
Check
Converter
Circuitry
3-16
->
Trace
Signal
2-12
I/O
PROBLEMS
2-21