EasyManua.ls Logo

Lexmark MS510 Series - Sensor (Input) Static Jam Service Check

Lexmark MS510 Series
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error code Description Action
200.38 Interpage servo gap smaller than expected for galvo
offset target evaluation.
Go to “Sensor (input) early/late arriving service
check” on page 61.
200.42 Rogue sheet at ACM sensor while flushing the paper
path prior to declaring tray 1 source empty.
200.44 Page from tray 1 did not reach the input sensor (or
the manual feed sensor, if present) after multiple pick
attempts. Page did make it out of the tray at least as
far as the ACM sensor.
200.45 During warm up flush, sheet detected too long over
input sensor.
Sensor (input) static jam service check
Action Yes No
Step 1
Check the input sensor area for jammed media fragments.
Is the paper path free of partially fed or jammed media?
Go to step 2. Clear the paper path of
any media fragments.
Step 2
Check the jam access cover if it is blocking the input sensor.
Is it blocking the input sensor?
Replace the jam access
cover. See “Jam access
cover removal” on
page 214.
Go to step 3.
Step 3
Check the input sensor cable for proper connection.
Is it properly connected?
Go to step 4. Reseat the cable.
Step 4
POR into the Diagnostics menu and perform a sensor test:
Diagnostics Menu > Base Sensor Test > Input.
Does the sensor state on the control panel display change when it is
toggled?
Go to step 5. Replace the input
sensor. See “Duplex
sensor and input
sensor removal” on
page 227.
Step 5
Does the error remain?
Contact the next level
of support.
The problem is solved.
4514-630, -635, -636
Diagnostic information
60

Table of Contents

Other manuals for Lexmark MS510 Series

Related product manuals