4-3
Door switch
Oven lamp
Inner Broil heater
Components Test procedures Results
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Door open Door closed
Continuity Infinite
1. Refer to page 3-7 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
Normal: Below 5 .
If not replace
1. Remove wire leads
2. Measure resistance after cooling down
Normal : Approximately 50
Abnomal : Infinite(opened)
NOTE: Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.