LINAK mounting bracket part no.: 0673003-A
The reason why it is important only to fix one column is that the
columns will not move exactly in parallel – even if you have positioning
such as hall.
If more than one column is fixed, it can lead to dangerous situations.
If you have trend/antitrend function in your application you need to mount
one or more of the BL4s with a slider.
Having sliders prevents the column from bending like illustrated below.
Mounting guidelines for the BL4 bracket, supplied by LINAK, part no. 0673003:
Mounting the bracket in the application:
The bracket must be mounted to an even abutting plate in the application by using the 2 slits.
In each slit at least 3 bolts must be mounted. Type M8 8.8.
Tightening moment must be 22.7 - 26.1 Nm.
The 3 bolts must be placed in the same height as the 3 holes.
Mounting of the BL4 into the bracket:
The BL4 must be fi tted in the bracket after mounting the bracket to the application.
3 bolts and nuts must be mounted in the 3 holes. Type M6 8.8
Tightening moment must be 10.3 ± 0.3 Nm
The mounting points must be re-tightened at least once a year with the above specified moments.
3 holes
2 slits

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Linak CBJ Home and is the answer not in the manual?

Linak CBJ Home Specifications

General IconGeneral
BrandLinak
ModelCBJ Home
CategoryController
LanguageEnglish

Related product manuals